A recent review article by Ramalho et al summarizes the literature on gadolinium-based contrast agents or GBCAs that are administered for contrast-enhanced MRIs, and it ties together information on agent stability, and animal and human studies.  The article, “Gadolinium-Based Contrast Agent Accumulation and Toxicity: An Update”, also emphasizes that the low-stability agents are the ones most often associated with brain deposition of gadolinium that has been reported in the literature since 2014.

Since the article has Open Access at AJNR.org, I will not go into all of the details of it.  However, there are some facts contained in the paper that I want to present here that are relevant to why GadoliniumToxicity.com exists.  In 2014, Hubbs Grimm and I created this website as a way to alert people to a problem that was not yet recognized by the FDA and medical industry.  That problem was gadolinium retention in patients with normal renal function.  We knew the facts were in the published literature, but they just had not been seen by the right people yet.   Thankfully, that has now begun to change.

Nephrogenic Systemic Fibrosis (NSF)
No review of GBCAs would be complete without some background information on NSF.

In 2006, the association between the administration of GBCAs and the development of Nephrogenic Systemic Fibrosis (NSF) in patients with severe renal disease was reported by Grobner and then by Marckmann et al.  NSF predominantly involves the skin, but it is a systemic disease that may also affect other organs such as the lungs, liver, heart, and muscles.  The exact pathophysiology of NSF remains unknown, but as the review states, the dissociation of gadolinium ions from their chelating ligands has been accepted as the primary etiology.  That is more likely to occur in patients with renal failure than in those with normal renal function since the excretion rate is reduced in those with renal failure.  The article indicates that most cases of NSF reported in the literature have been associated with the administration of nonionic, linear gadodiamide (Omniscan, GE Healthcare), nonionic, linear gadoversetamide (OptiMARK, Covidien), and with ionic, linear gadopentetate dimeglumine (Magnevist, Bayer HealthCare Pharmaceuticals).

After limiting the use of GBCAs in patients with renal failure and using more stable GBCAs, there have been no new cases of NSF reported since mid-2009.  According to the paper, from 2009 to 2014, confidence in the safety of GBCAs had been largely restored.  However, since 2014, numerous studies have been published that reported finding evidence of gadolinium deposition in neural tissues in patients with normal renal function. (more…)

Gadolinium Deposition in Humans is Not Something New

Since early 2014, there have been numerous articles published that report finding evidence of gadolinium deposition in the brain within the dentate nucleus (DN) and globus pallidus (GP) in patients with normal renal function.  The findings seem to have come as a surprise to some radiologists, but a review article by Huckle et al indicates that no one should be surprised by the findings.  The article, Gadolinium Deposition in Humans – When did we learn that Gadolinium was deposited in vivo?, takes a retrospective look back at gadolinium-based contrast agents (GBCAs) to describe the historical evidence of gadolinium (Gd) deposition in vivo.  According to the authors, it “shows that deposition in the basal ganglia should come as no surprise”.

The article notes that deposition of gadolinium in animals with normal renal function has been described in the peer-reviewed literature since at least 1984 when Weinmann et al reported that although gadolinium elimination in rats was largely complete 7 days after administration of Gd-DTPA, a small fraction (0.3%) was retained.  Other animal studies confirmed gadolinium retention that was proportional to the dose.  Gadolinium was found in bone, skin, and other organs in animals.

The higher stability of macrocyclic GBCAs compared to the linear agents has been confirmed in published animal studies.  However, while higher levels of gadolinium were detected in the skin and bones of animals injected with linear agents, the studies demonstrated that “quantifiable levels of gadolinium” are deposited after administration of all GBCAs – linear and macrocyclic agents.

(more…)

MRI brain signal changes reported in a child

The November 2015 issue of Pediatrics includes a case study by Miller et al.  The article, MRI Brain Signal Intensity Changes of a Child During the Course of 35 Gadolinium Contrast Examinations, describes the quantitative signal intensity changes in the brain of a pediatric patient who had 35 MRIs with a linear gadolinium-based contrast agent (GBCA) between the ages of 8 and 20 years.  The authors report that progressive increases were the most evident in the dentate nuclei, the globus pallidus, and the thalamus.  They noted that the pattern of regional brain hyperintensity observed is consistent with findings from recent adult studies.

High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted images was first reported by Kanda et al in late 2013 and has been found to be the result of gadolinium deposition in the brain.

Sharon Williams

________________________________________________________________________

Miller, J. H., Hu, H. H., Pokorney, A., Cornejo, P., & Towbin, R. (2015). MRI Brain Signal Intensity Changes of a Child During the Course of 35 Gadolinium Contrast Examinations. Pediatrics, peds.2015–2222–. http://doi.org/10.1542/peds.2015-2222

Kanda, T., Ishii, K., Kawaguchi, H., Kitajima, K., & Takenaka, D. (2013). High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-weighted MR Images: Relationship with Increasing Cumulative Dose of a Gadolinium-based Contrast Material. Radiology, 131669. http://doi.org/10.1148/radiol.13131669

New study did not find signal increases in brain after repeat administrations of Gadovist.

A new study by Radbruch et al concerning gadobutrol has been published online ahead-of-print in Investigative Radiology.  The paper, High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images: Evaluation of the Macrocyclic Gadolinium-Based Contrast Agent Gadobutrol, did not find signal increases in the dentate nucleus (DN) or in the globus pallidus (GP) after serial administrations of gadobutrol (Gadovist, Bayer Healthcare).  The study included 30 patients who had received at least 5 MRI examinations with only Gadovist.

The findings are in contrast to a previously published study by Stojanov et al that we reported about.  That paper was titled, Increasing signal intensity within the dentate nucleus and globus pallidus on unenhanced T1W magnetic resonance images in patients with relapsing-remitting multiple sclerosis: correlation with cumulative dose of a macrocyclic gadolinium-bases contrast agent, gadobutrol (European Radiology, 2015). 

Radbruch and his colleagues concluded that their finding “adds further support to the hypothesis that the molecular structure of a gadolinium-based contrast agent as either macrocyclic or linear is a crucial factor for its potential to cause gadolinium deposition in the brain”.  The authors also noted that future studies are needed to assess this hypothesis.

I agree that additional research is needed.  I would be interested to find out if gadolinium from macrocyclic agents is being deposited in the brain, but perhaps in smaller quantities than from linear agents.  If so, it might be that the amount of deposited gadolinium has to reach a certain level before signal increases are detected on magnetic resonance images (MRI).  Still to be determined are the long-term effects of any amount of gadolinium deposition in the brain or elsewhere in the body.

Sharon Williams

____________________________________________________________

Radbruch, A., Weberling, L. D., Kieslich, P. J., Hepp, J., Kickingereder, P., Wick, W., … Bendszus, M. (2015). High-Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images: Evaluation of the Macrocyclic Gadolinium-Based Contrast Agent Gadobutrol. Investigative Radiology, 50(12). Retrieved from http://journals.lww.com/investigativeradiology/Fulltext/2015/12000/High_Signal_Intensity_in_the_Dentate_Nucleus_and.1.aspx

Stojanov, D. A., Aracki-Trenkic, A., Vojinovic, S., Benedeto-Stojanov, D., & Ljubisavljevic, S. (2015). Increasing signal intensity within the dentate nucleus and globus pallidus on unenhanced T1W magnetic resonance images in patients with relapsing-remitting multiple sclerosis: correlation with cumulative dose of a macrocyclic gadolinium-based contrast age. European Radiology. http://doi.org/10.1007/s00330-015-3879-9

%d bloggers like this: